Fluorescent Is Finished: The UK Retrofit Guide for Contractors and Building Owners

The fluorescent phase out in the UK is complete. T8 tubes in 2ft, 4ft and 5ft lengths were banned from sale on 1 September 2023, T5 and long-life T8 followed on 1 February 2024, and the final exemptions for certain T9 circular and special-purpose lamps expired on 24 February 2025. Working fluorescents can stay in place, but when a tube fails there is no like-for-like replacement on the market. The only practical route is an LED retrofit, and this guide explains how to do it well.
Signature LED Lighting has been supplying the electrical trade since 2017 from its base in Liverpool. This guide is written for the people who deal with the phase out in practice: the contractor standing under a dead 5ft twin batten, the wholesaler deciding what to put on the shelf, and the facility manager watching a ceiling go dark one luminaire at a time.
What exactly has been banned, and when?
The bans came through amendments to the RoHS regulations, which restrict hazardous substances in electrical equipment. Fluorescent lamps contain mercury, and the exemptions that allowed them to stay on sale have now all expired in Great Britain. The timeline ran as follows:
- 1 September 2023: T8 fluorescent tubes in 2ft, 4ft and 5ft lengths could no longer be placed on the market.
- 1 February 2024: T5 tubes and long-life T8 tubes followed.
- 24 February 2025: the final exemptions for certain T9 circular lamps and special-purpose lamps expired.
“Banned from sale” has a specific meaning here. Manufacturers and importers can no longer place these lamps on the GB market. Wholesalers were allowed to sell through existing stock, and most of that stock has long since gone. The official detail sits in the government guidance on RoHS, which is worth bookmarking if a client asks for chapter and verse.
There is one more wrinkle worth knowing. The bans were made under GB RoHS, the framework that restricts mercury and other hazardous substances in electrical equipment sold in Great Britain. For practical purposes the result is consistent across the country: the replacement tube era is over. Contractors quoting maintenance contracts should price on that basis, because a contract that assumes tube availability is a contract that will lose money. Wholesale counter staff report the same pattern: customers asking for tubes leave with a conversation about battens, gear trays or panels instead.
Do working fluorescents have to be removed?
No. There is no legal duty to rip out working fluorescent luminaires. A 4ft twin batten that still strikes every morning can keep running until it fails. The phase out targets the supply of new lamps, not the use of existing ones.
That distinction matters because it shapes the conversation with clients. Nobody is forcing them to act today. What the phase out does is remove the cheap option they have relied on for decades: the £3 replacement tube. When a tube fails now, the realistic choices are a drop-in LED gear tray, a new LED luminaire, or a dark patch of ceiling. Spot relamping a 200-fitting warehouse stops being maintenance and becomes a rolling refurbishment, whether the owner planned one or not.
Some installers still find old tubes in the back of a stores cupboard. Fitting them is legal, but it only postpones the decision by one lamp life, and it leaves the building running at 60 to 80 lm/W when modern LED delivers 140 to 160+ lm/W. The maths rarely favours waiting.
Why is this driving a retrofit wave now?
Fluorescent failure is not a cliff edge, it is a slope. Tubes fail at different rates depending on switching cycles, ambient temperature and age, so buildings lose light gradually. Through 2023 and 2024 most sites coasted on stockpiled tubes. By 2025 the stockpiles were thin and the final exemptions had expired. In 2026 the failures are landing on sites with no tubes left to fit, which is why contractors are seeing the same call again and again: half the lights in the workshop are out, what do we do?
The answer is rarely “replace one fitting”. Once a client accepts that the first failed luminaire needs an LED solution, the sensible move is to plan the whole area, because mixing one new 4000K LED batten into a row of tired 60 lm/W fluorescents looks wrong and wastes a site visit. A free lighting design service turns a distress purchase into a planned scheme: correct lumen packages, correct spacing, and a like-for-like or better light level on the working plane.
How do the numbers compare: fluorescent vs LED?
Three generations of efficacy tell the story:
- Fluorescent: 60 to 80 lm/W, and that is lamp efficacy before control gear losses.
- First-generation LED: 90 to 110 lm/W, the early retrofit products from a decade ago.
- Modern LED: 140 to 160+ lm/W as a complete system, luminaire and driver included.
Worked example. A 5ft twin T8 batten draws roughly 116W with control gear losses included. A modern LED batten replacing it can deliver the same or better light on the task at 40 to 50W. Take a unit running 12 hours a day, 5 days a week: that is around 3,120 hours a year. The fluorescent burns about 362 kWh a year; the 45W LED burns about 140 kWh. At 25p per kWh the saving is roughly £55 per fitting per year. Across a 100-fitting workshop that is about £5,500 a year before maintenance savings, and the maintenance savings are real: no more tube and starter changes from a scissor lift.
When you compare products, watch the difference between chip efficacy and system efficacy. A datasheet boasting 200 lm/W at chip level can still deliver a mediocre luminaire once driver losses, optics and thermal derating are counted. Always quote and compare system lm/W, check the L70 lifetime figure, and ask about the driver lifetime, because the driver usually fails before the LEDs do.
What is the retrofit decision tree?
Every failed fluorescent luminaire leads to one of three routes. Here is the logic we use on design enquiries.
Route 1: drop-in gear tray conversion
If the existing luminaire body is sound, sealed and doing its job, you do not have to throw it away. A Dual Wattage CCT gear tray drops into an existing bulkhead or fitting body, replacing the lamp, control gear and gear tray in one piece. Selectable wattage and CCT mean one unit covers multiple existing fittings. This route shines on amenity bulkheads, stair cores and corridors where the housings are recent and access is easy. It is the fastest swap and the lowest material cost per point.
Route 2: new LED luminaire
If the body is corroded, brittle, discoloured or simply old, fit new. For open-area linear lighting the workhorse is the batten. The Magni 9-in-1 batten comes in 2ft, 4ft, 5ft and 6ft, with selectable wattage and CCT: the 4ft version switches between 20W, 30W and 40W, delivering 2,800, 4,200 or 5,600 lumens at 140 lm/W. For wet, dusty or unheated spaces, a non-corrosive such as the Nemesis Pro gives IP65 ingress protection and IK08 impact resistance with dual wattage and a CCT dip switch. For continuous architectural runs, the Selene linear delivers 120 lm/W with CRI above 90 and a TP(a) diffuser in lengths from 0.5m to 2.1m.
Route 3: panel replacement for modular ceilings
Where the fluorescents sit in a suspended ceiling grid, 600×600 and 1200×600 modulars come out and Loki LED panels go straight into the same grid. No re-wiring of the ceiling layout, no tile cutting, and a flat, even appearance that suits offices, classrooms and reception areas. The labour saving is the point: a competent pair can swap a panel in minutes, so a floor of forty fittings is a short programme rather than a week of upheaval, and the work can run out of hours with minimal making good.
The honest rule of thumb: gear tray when the body is good, new luminaire when it is not, panel when the ceiling is modular. If a site mixes all three, a lighting design pulls the whole thing into one coherent scheme and one delivery.
How does the phase out play out sector by sector?
Industrial and warehousing
High mounting heights and long burn hours make this the sector with the fastest payback. 5ft and 6ft twin fluorescents are everywhere, and every failure means access equipment. Replace with 5ft or 6ft battens or, in wash-down and unheated areas, non-corrosives with microwave sensors so the lights only run when someone is in the aisle. Sensor control on top of an LED swap typically takes another large slice off the energy figure in low-traffic zones.
Commercial offices
The classic estate is 600×600 modular fluorescent in a suspended grid. The swap is LED panels, with attention to glare: choose panels with appropriate UGR performance for screen-based work, and use the design service to confirm lux levels against CIBSE office guidance. CCT selection matters here too: 4000K is the usual office choice.
Car parks, plant rooms and external canopies
Cold, damp and occasionally knocked about. This is non-corrosive territory: IP65 against moisture and dust, IK08 against impacts. Rugby Borough Council fitted 365 Nemesis Pro vapour-proof fittings at John Bamford Carpark, a good illustration of the scale a single car park retrofit can reach. Dual wattage means one SKU can serve both the parking decks and the brighter ramp areas.
Healthcare and care environments
Continuous occupation, sensitive occupants and strict cleaning regimes. CCT selectable products earn their keep because day areas, corridors and night-lit zones want different colour temperatures from the same stock item. St. George Health Care Group used Gaia CCT bulkheads for exactly this flexibility. Gear tray conversions also suit healthcare corridors where the existing bulkhead bodies are sound and downtime must be minimal.
Education and public buildings
Mixed estates: modular ceilings in classrooms and offices, battens in halls and workshops, bulkheads in stairwells. Summer holidays are the natural installation window, which is one reason July and August retrofit planning matters. A whole-school scheme usually combines panels, battens and gear trays from a single design.
Retail and hospitality
Back-of-house areas still run fluorescent battens long after the shopfloor went LED. Kitchens and cold stores need IP65 non-corrosives; store rooms and service corridors take standard battens or gear tray conversions. CRI matters front of house: the Selene linear at CRI above 90 keeps colour rendering honest where merchandise or food is on display.
What should wholesalers stock for the retrofit wave?
The phase out rewards wholesalers who simplify. The old fluorescent world needed deep stock: multiple tube lengths, wattages, colour temperatures, starters and chokes. Selectable LED products collapse that range.
- Battens: the Magni 9-in-1 covers three wattages and three CCTs in one box. Nine specifications from one SKU per length means a 2ft, 4ft, 5ft and 6ft holding of four products replaces what used to be dozens of lines. The same logic applies to a contractor’s van stock: one batten on the shelf answers nine job specs.
- Non-corrosives: Nemesis Pro in 4ft 20 and 40W, 5ft 25 and 50W, and 6ft 35 and 70W, all with the 4000K, 5000K and 6500K dip switch, plus plug and play microwave sensor and emergency accessories on the 5ft and 6ft. Stock the fitting, stock the accessories, and every car park or plant room enquiry is covered.
- Gear trays: Dual Wattage CCT gear trays answer the bulkhead question without stocking a wall of complete fittings.
- Panels: 600×600 and 1200×600 Loki panels for every office and school enquiry.
Signature LED products are available through wholesalers and CEF nationwide. For branches that want to get counter staff up to speed on selectable products and the phase out timeline, Breakfast Mornings bring the technical team to the trade counter with product in hand.
What about disposing of the old fluorescent lamps?
Fluorescent tubes contain mercury, so they are hazardous waste and fall under the WEEE regulations. They must never go in general waste or a mixed skip. Use a licensed WEEE collection or a wholesaler take-back scheme, keep the tubes unbroken in their boxes or a dedicated lamp container, and retain the waste transfer documentation. The official WEEE guidance sets out producer and distributor obligations, and larger retrofit projects should price lamp disposal into the job from the start. A 200-fitting twin-tube site produces 400 mercury-bearing lamps; that is a logistics line item, not an afterthought.
How should a contractor plan a phase out project?
A repeatable process keeps retrofit jobs profitable:
- Survey: count fittings by type, length, lamp configuration and condition. Note ceiling types, mounting heights and any damp or impact-prone areas.
- Decide routes: gear tray, new luminaire or panel for each area, using the decision tree above.
- Design: send the survey to the free lighting design service for lux calculations, product selection and a fitting schedule. This is also the document that wins the client’s sign-off.
- Programme: order against the schedule. Same-day delivery across the North West on orders placed before 1pm, next-day nationwide, and free delivery on orders over £150 mean stock arrives when the access equipment does. Full details are on the delivery information page.
- Install and commission: set dip switches for wattage and CCT before fitting where possible, and record the settings on the O&M sheet so the next electrician knows what each luminaire is set to deliver.
- Handover: photograph the completed areas, log the warranty start date, and leave the client with the design document. It is the cheapest sales tool there is for the next phase of the same building.
- Dispose: WEEE-compliant lamp collection, documented.
Every product is backed by a 5-year warranty, two years of it on site, which gives the contractor a clean answer when the client asks who stands behind the installation.
Frequently asked questions
Can I still buy fluorescent tubes anywhere?
Not legitimately as new stock placed on the GB market. The sales bans took effect in September 2023 for T8, February 2024 for T5 and long-life T8, and the final T9 circular and special-purpose exemptions expired in February 2025. Some old stock circulated for a while after each date because sell-through of existing inventory was permitted, but that stock is essentially exhausted. If a supplier offers new fluorescent tubes today, ask hard questions about where they came from. The practical position for any contractor or facility manager is simple: plan every fluorescent failure as an LED conversion, because the next failure on the same site is already on its way.
Is it illegal to keep using my existing fluorescent lighting?
No. The RoHS amendments ban placing the lamps on the market; they do not ban using lamps already installed. A working fluorescent luminaire can stay in service indefinitely. The pressure is economic and practical rather than legal: you cannot buy replacement tubes when they fail, the energy cost per lumen is roughly half what modern LED achieves, and maintaining a dwindling fluorescent estate means hoarding obsolete spares. Most building owners choose a planned retrofit on their own timetable rather than an unplanned one dictated by failures, and a planned scheme is almost always cheaper per fitting.
Can I just fit an LED retrofit tube in my existing fluorescent fitting?
Retrofit LED tubes exist, but they deserve caution. Many require the fitting to be re-wired to bypass the control gear, which modifies the luminaire and shifts responsibility for its safety onto whoever modified it. The old lamp holders, wiring and body may be decades old, and the result is a new light source in a tired luminaire at perhaps 100 to 110 lm/W. A purpose-built LED batten at 140 lm/W, or a drop-in gear tray that renews the electrical heart of a sound body, gives better efficacy, a proper warranty and a cleaner liability position. For most trade installations the retrofit tube is the weakest of the available options.
What happens to the light level if I swap one-for-one?
Usually it improves, but check rather than assume. A 5ft twin fluorescent batten produces in the region of 9,000 lamp lumens, of which a good portion is lost in the luminaire. A 5ft LED batten set to its higher wattage can deliver comparable or better delivered light at less than half the energy. The variables are mounting height, spacing, surface reflectance and the task below. The safe route on anything bigger than a single room is a lighting design with proper calculations, which Signature LED provides free of charge. It confirms lux on the working plane before anyone orders a box of fittings.
Which colour temperature should I choose?
Selectable CCT products make this less of a gamble, but the usual answers are: 4000K for offices, schools, healthcare day areas and most commercial interiors; 5000K for workshops, warehouses and task areas where alertness and detail matter; 6500K only where a very cool, daylight-type appearance is wanted, such as some industrial inspection areas. With a dip switch product like the Nemesis Pro or a selectable batten like the Magni, the installer sets the CCT on site, and can change it later if the client changes their mind. One practical tip from the trade counter: agree the CCT with the client before installation day, set every fitting on the bench, and label the boxes. It saves a second trip up the ladder and avoids the mixed-white ceiling that makes a tidy job look careless.
Do I need an emergency lighting version?
If the fluorescent fitting being replaced was an emergency unit, or the escape route design requires one at that location, yes. Emergency provision must be maintained when luminaires are replaced, and a retrofit is a sensible moment to review the whole emergency layout against current requirements. The Nemesis Pro range takes plug and play emergency accessories on the 5ft and 6ft sizes, which keeps the emergency points within the same product family as the rest of the scheme. Guidance on workplace lighting duties is available from the Health and Safety Executive.
How long will the LED replacements last?
Look for the L70 figure: the number of operating hours before light output falls to 70 percent of initial. Modern trade-quality LED luminaires commonly quote L70 lifetimes of 50,000 hours or more, which at 3,000 burn hours a year is well over a decade of service. Check the driver lifetime separately, because the driver is the component most likely to fail first, and a luminaire with replaceable gear is easier to keep in service. Signature LED backs its products with a 5-year warranty, two years of it on site.
Next step: turn failures into a plan
The fluorescent phase out has already happened; the only question is whether each building responds to it fitting by fitting or as a planned scheme. Send your site survey or fitting count to the free lighting design service and get back a costed, calculated proposal, or ask your local wholesaler or CEF branch for Signature LED selectable battens, gear trays, non-corrosives and panels. Orders before 1pm go out same-day across the North West, next-day nationwide, free over £150. Speak to the team via the contact page and turn the next failed tube into the start of the upgrade.
Free lighting design
Send us your plans. Our in-house engineers return lux plots, UGR checks and a fitting schedule, with a rapid turnaround and no charge.
Request a design